Overview
|
HP Smart Array P411 Controller |
|
The HP Smart Array P411 is HP's external connect only, PCI Express (PCIe) 2.0 Serial Attached SCSI (SAS) RAID controller. The low profile, half height card has 8 ports and utilizes DDR2-800 memory. The P411 is ideal for RAID 0, 1, 1+0, 5, 5+0 and can be upgraded with a minimum of 256MB cache module, battery kit (for BBWC),,and Smart Array Advanced Pack license key for RAID 6 (ADG) & 6+0. |
|
|
| |
| What's New |
|
|
|
| Models | ||
| HP Smart Array P411 Controller |
HP Smart Array P411/256MB Controller
|
462830-B21
|
| HP Smart Array P411/512MB Battery Backed Write Cache |
462832-B21
|
|
|
|
||
| Upgrade Options | ||
| Optional Upgrades | 512MB BBWC |
462967-B21
|
| Battery Kit upgrade NOTE: To enable BBWC on the 256MB cache. |
462969-B21 | |
| HP Smart Array Advanced Pack No
Media 1-Server license including 1yr 24x7 Technical Support NOTE: This part number can be used to purchase a single license or to order multiple licenses with a single activation key. Customers will receive a license entitlement certificate via e-mail. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Include one year of 24x7 HP Software Technical Support Services. NOTE: A license key, a minimum of 256MB cache, and battery kit is required to enable features. For more information go to: http://www.hp.com/go/saap |
516471-B21 | |
|
|
Standard Features
| The Smart Array Advantage |
HP's innovative design and integration work of the Smart Array family of products creates customer value that is unmatched in the industry. Use of Smart Array products across multiple applications results in a much lower Total Cost of Ownership (TCO) than any other server storage RAID product. The HP Smart Array family brings an unparalleled return on investment through: |
| Data Compatibility among all models of Smart Array controllers allows simple and easy upgrades any time needs for higher performance, capacity, and availability increase. Even successive generations of Smart Array controllers understand the data format of other Smart Array Controllers. | |
| Consistent Configuration and Management Tools. All Smart Array products utilize a standard set of management and utility software. These tools minimize Total Cost of Ownership (TCO) by reducing training requirements and technical expertise necessary to install and maintain the HP server storage. | |
| Universal Hard Drive form factor is for use across multiple HP servers, disk enclosures and storage systems. With compatibility across many enterprise platforms, you are free to deploy and re-deploy these drives to quickly deliver increased storage capacity, migrate data between systems, and easily manage spare drives. | |
| Pre-Failure Warranty means HP Insight Manager not only reports when a drive is going to fail but allows replacement of failing drives prior to actual failure. For complete details, consult the HP Support Center or refer to your HP Server documentation. | |
|
|
|
| Key Features |
|
|
|
|
| Online Management Features |
|
|
|
|
| Ports |
|
|
|
|
|
Performance |
HP's High Performance Architecture sets new boundaries of industry performance expectations!
|
|
| |
| Native Command Queuing |
Native Command Queuing (NCQ) is a technology designed to increase performance
of SATA hard disk drives by allowing the individual hard disk to internally
optimize the order in which received read and write commands are executed.
This can reduce the amount of unnecessary going back-and-forth on the
drive's heads, resulting in increased performance for workloads where
multiple simultaneous read/write requests are outstanding, most often
occurring in server or storage-type applications. Without NCQ the drive
has to process and complete one command at a time. For NCQ to be enabled,
it must be supported and turned on in the controller and in the hard drive
itself. |
| | |
| Capacity |
Given the increasing need for high performance and rapid capacity expansion, the SA-P411 offers:
NOTE: Support for greater than 2TB in a single logical drive. |
| | |
|
Availability |
Provides increased server uptime by providing advanced storage functionality:
|
|
|
|
|
Fault Prevention |
The following features offer detection of possible failures before they occur, allowing preventive action to be taken:
|
|
|
|
|
Fault Tolerance |
Keeps data available and server running while a failed drive is being replaced; several fault tolerance configurations are supported including:
|
|
|
|
|
Fault Recovery |
Minimizes downtime, reconstructs data, and facilitates a quick recovery from drive failure
|
|
|
|
| Ease of Use |
Consistency and Upgradeability make the Smart Array family unique in the industry:
|
|
|
|
Compatibility
| Server Support | For up to date compatibility, please see
the following URL for complete Smart Array P411 Controller compatibility
and support information: http://h18006.www1.hp.com/products/servers/proliantstorage/arraycontrollers/index.html |
|
| |
| Operating Systems | Microsoft Windows 2003 x64 |
| Microsoft Windows 2003 | |
| Microsoft Windows 2003 x84 | |
| Microsoft Windows 2008 Server x64 | |
| Microsoft Windows 2008 Server x84 | |
| Novell Open Enterprise Server, NetWare 6.5 | |
| SP5 | |
| Red Hat Enterprise Linux 4, 5, & 6 (x64 & x84) | |
| SUSE Linux Enterprise Server 9 (x64 & x84) | |
| SUSE Linux Enterprise Server 10 (x64 & x84) | |
| SUSE Linux Enterprise Server 11 (x64 & x84) | |
| VMWare | |
|
NOTE: For more Linux OS support & certification information, please visit:
|
|
| | |
| Software Suite | All Smart Array products share a common set of configuration, management and diagnostic tools, including Array Configuration Utility (ACU), Array Diagnostic Utility (ADU), and Systems Insight Manager. These software tools reduce the cost of training for each successive generation of product and takes much of the guesswork out of troubleshooting field problems. These tools lower the total cost of ownership by reducing training and technical expertise necessary to install and maintain HP server storage. |
| Systems Insight Manager | |
|
|
| HP Array Configuration Utility (ACU) | |
|
|
| HP Option ROM Configuration for Arrays (ORCA) | |
NOTE: For advanced array configurations use ACU. |
|
| HP Array Diagnostic Utility (ADU) | |
|
|
|
Service and Support, HP Care Pack, and Warranty Information
| Warranty | The warranty for this device is 3 years parts only. |
| Pre-Failure Warranty: Drives attached to the Smart Array Controller and monitored under Insight Manager are supported by a Pre-Failure (replacement) Warranty. For complete details, consult the HP Support Center or refer to your HP Server Documentation. | |
|
|
|
| Software Product Services |
Standalone telephone support
|
| Rights to new license version | |
| Media and documentation updates | |
|
|
|
| Hardware Product Services | Installation services |
| On-site maintenance (includes warranty support) | |
| Response time upgrades during the warranty period | |
| Post-warranty coverage | |
| RAID setup and performance consulting via statement of work | |
| NOTE: For additional
hardware installation and maintenance information, please refer to the URL:
http://www.hp.com/hps/hardware/ |
|
|
|
|
| Warranty Upgrade Options | Response - Upgrade on-site response from next business day to same day 4 hours |
| Coverage - Extend hours of coverage from 9 hours x 5 days to 24 hours x 7 days | |
| Duration - Select duration of coverage for a period of 1, 3, or 5 years | |
| Warranty upgrade options can come in the form of Care Packs, which are sold at the HP System level this product attaches too. | |
|
|
|
| HP Care Pack Information | HP Care Pack is defined as an upgrade to the product warranty attribute, available for a specific duration and hours of coverage. Care Packs for this option is sold at the system level this option attaches too. | |
| HP Care Pack is not available for less than the product's warranty duration. | ||
| HP Care Pack is available for sale anytime during the warranty period for most products, but the commencement date will be the same as the Warranty Start Date (delivery date to end user customer). Proof of purchase may be required. | ||
| HP Care Pack services are prepaid. | ||
| NOTE: For additional HP Care Pack (hardware & software) information, as well as orderable part numbers, please refer to the URL: http://www.hp.com/hps/carepack/ | ||
|
|
Related Options
| NOTE: This is a list of supported options. Some may be discontinued. | ||
| Hard Drives | NOTE: The components
of a storage subsystem (e.g. the drive, the HBA/controller, firmware, and
the server backplane) should operate at the same data transfer rate or the
system bandwidth will be negotiated down to an acceptable level for all
components. NOTE: Hard drives have either a one year or three year warranty; refer to the specific hard drive QuickSpecs for details. |
|
| SAS Hot Plug SFF Enterprise (ENT) Drives | ||
| HP 300GB 6G SAS 10K SFF DP ENT HDD | 507127-B21 | |
| HP 300GB 3G SAS 10K SFF DP ENT HDD | 492620-B21 | |
| HP 146GB 6G SAS 15K SFF DP ENT HDD | 512547-B21 | |
| HP 146GB 3G SAS 15K SFF DP ENT HDD | 504062-B21 | |
| HP 146GB 6G SAS 10K SFF DP ENT HDD | 507125-B21 | |
| HP 146GB 3G SAS 10K SFF DP ENT HDD | 418367-B21 | |
| HP 72GB 6G SAS 15K SFF DP ENT HDD | 512545-B21 | |
| HP 72GB 3G SAS 15K SFF DP ENT HDD | 418371-B21 | |
| SAS Hot Plug 3.5" Enterprise (ENT) Drives | ||
| HP 600GB 6G SAS 15K 3.5" DP ENT HDD | 516828-B21 | |
| HP450GB 6G SAS 15K 3.5" DP ENT HDD | 516816-B21 | |
| HP 450GB 3G SAS 15K 3.5" DP ENT HDD | 454232-B21 | |
| HP 400GB 3G SAS 10K 3.5" DP ENT HDD | 459508-B21 | |
| HP 300GB 6G SAS 15K 3.5" DP ENT HDD | 516814-B21 | |
| HP 300GB 3G SAS 15K 3.5" DP ENT HDD | 416127-B21 | |
| HP 146GB 3G SAS 15K 3.5" DP ENT HDD | 384854-B21 | |
| SAS Non-Hot Plug 3.5" Enterprise (ENT) Drives | ||
| HP 600GB 6G SAS 15K NHP3.5" DP ENT HDD | 516830-B21 | |
| HP 450GB 6G SAS15K NHP 3.5" DP ENT HDD | 516826-B21 | |
| HP 450GB 3G SAS 15K NHP 3.5" DP ENT HDD | 454234-B21 | |
| HP 400GB 3G SAS 10K NHP 3.5" DP ENT HDD | 508232-B21 | |
| HP 300GB 6G SAS 15K NHP 3.5" DP ENT HDD | 516824-B21 | |
| HP 300GB 3G SAS 15K NHP 3.5" DP ENT HDD | 417950-B21 | |
| HP 146GB 3G SAS 15K NHP 3.5" DP ENT HDD | 417855-B21 | |
| SAS Hot Plug SFF Midline (MDL) Drives | ||
| HP 500GB 6G SAS 7.2K SFF DP MDL HDD | 507610-B21 | |
| SAS Hot Plug 3.5" Midline (MDL) Drives | ||
| HP 1TB 3G SAS 7.2K 3.5" DP MDL HDD | 461137-B21 | |
| HP 750GB 3G SAS 7.2K 3.5" DP MDL HDD | 461135-B21 | |
| SATA Hot Plug SFF Midline (MDL) Drives | ||
| HP 500GB 3G SATA 7.2K 2.5in MDL HDD | 507750-B21 | |
| HP 160GB 3G SATA 7.2K 2.5in MDL HDD | 530888-B21 | |
| SATA Non-Hot Plug SFF Midline (MDL) Drives | ||
| HP 500GB 3G SATA 7.2K 2.5in NHP MDL HDD | 507753-B21 | |
| HP 160GB 3G SATA 7.2K 2.5in NHP MDL HDD | 530891-B21 | |
| SATA Hot Plug SFF Entry (ETY) Drives | ||
| HP 250GB 3G SATA 5.4K SFF ETY HDD | 460355-B21 | |
| HP 120GB 1.5G SATA 5.4K SFF ETY HDD | 458924-B21 | |
| SATA Non-Hot Plug SFF Entry (ETY) Drives | ||
| HP 250GB 3G SATA 5.4K NHP SFF ETY HDD | 460357-B21 | |
| HP 120GB 1.5G SATA 5.4K NHP SFF ETY HDD | 459357-B21 | |
| SATA Hot Plug 3.5" Midline (MDL) Drives | ||
| HP 1TB 3G SATA 7.2K 3.5" MDL HDD | 454146-B21 | |
| HP 750GB 3G SATA 7.2K 3.5" MDL HDD | 458930-B21 | |
| HP 500GB 3G SATA 7.2K 3.5" MDL HDD | 458928-B21 | |
| HP 250GB 3G SATA 7.2K 3.5" MDL HDD | 458926-B21 | |
| SATA Hot Plug 3.5" Entry (ETY) Drives | ||
| HP 160GB 3G SATA 7.2K 3.5" ETY HDD | 458945-B21 | |
| SATA Non-Hot Plug 3.5" Midline (MDL) Drives | ||
| HP 750GB 3G SATA 7.2K NHP 3.5" MDL HDD | 462595-B21 | |
| HP 500GB 3G SATA 7.2K NHP 3.5" MDL HDD | 458941-B21 | |
| HP 250GB 3G SATA 7.2K NHP 3.5" MDL HDD | 458939-B21 | |
| SATA Non-Hot Plug 3.5" Entry (ETY) Drives | ||
| HP 160GB 3G SATA 7.2K NHP 3.5" ETY HDD | 458947-B21 | |
| NOTE: Go to the HP Hard Drive Compatibility table for complete drive compatibility information (http://www.hp.com/products/harddiskdrives). Using hard drives in unsupported configurations will result in voiding the warranty and could result in damage to the drive and/or loss of data. | ||
|
|
||
| HP StorageWorks Modular Smart Array | MSA SAN Storage Arrays | |
| HP StorageWorks 60 Modular Smart Array | 418408-B21 | |
| NOTE: Please see the Modular Smart Array 60 QuickSpecs for additional information including configuration steps and additional options needed for a complete solution at: http://h18000.www1.hp.com/products/quickspecs/12627_na/12627_na.html | ||
| HP StorageWorks 70 Modular Smart Array | 418800-B21 | |
| NOTE: Please see the Modular Smart Array 70 QuickSpecs for additional information including configuration steps and additional options needed for a complete solution at: http://h18000.www1.hp.com/products/quickspecs/12652_na/12652_na.html | ||
|
|
||
| HP StorageWorks Disk Enclosures | HP StorageWorks D2600 Disk Enclosure | AJ940A |
| HP StorageWorks D2700 Disk Enclosure | AJ941A | |
| NOTE: Please see the QuickSpecs for additional information including configuration steps and additional options needed for a complete solution at: http://h18000.www1.hp.com/products/quickspecs/13404_na/13404_na.html | ||
|
|
||
| HP StorageWorks Modular Disk System |
HP MDS600 with two Dual Port
I/O Module System NOTE: Please see the QuickSpecs for additional information including configuration steps and additional options needed for a complete solution at: http://h18000.www1.hp.com/products/quickspecs/13257_na/13257_na.html |
AJ866A |
|
|
||
| Tape Solutions | SAS Tape Drives | |
| HP StorageWorks DAT 160 SAS External Tape Drive |
Q1588A
|
|
| HP StorageWorks LTO-2 Ultrium 448 SAS External Tape Drive |
DW086A
|
|
| HP StorageWorks LTO-3 Ultrium 920 SAS External Tape Drive |
EH848A
|
|
| HP StorageWorks LTO-4 Ultrium 1760 SAS External Tape Drive |
EH920A
|
|
| HP StorageWorks 1U SAS Rack-Mount Kit with one LTO-4 Ultrium 1760 |
EH946A
|
|
| HP StorageWorks LTO-4 Ultrium 1840 SAS External Tape Drive |
EH861A
|
|
| Rack-mount Tape Drive Enclosures | ||
| HP StorageWorks 1U SAS Rack-Mount
Kit NOTE: The 1U SAS Rack-Mount Kit can support up to (2) half-height tape drives and is compatible with the DAT 160 SAS (Q1587A), LTO-2 Ultrium 448 SAS (DW085A), LTO-3 Ultrium 920 SAS (EH847A) and LTO-4 Ultrium 1760 (EH919A) tape drives. |
AE459A
|
|
| HP StorageWorks 3U SAS Rack-mount
Kit NOTE: The 3U Rack-mount Kit can support up to (2) full-height or (4) half-height tape drives and compatible with multiple SAS tape drives including DAT 160 SAS (Q1587A), LTO-2 Ultrium 448 SAS (DW085A), LTO-3 Ultrium 920 SAS (EH847A), LTO-4 Ultrium 1760 SAS (EH919A) and LTO-4 Ultrium 1840 SAS (EH860A) tape drives. |
AG576A
|
|
| Tape Autoloaders | ||
| HP StorageWorks 1/8 G2 LTO-4 Ultrium 1760 SAS Autoloader | AK377A | |
| HP StorageWorks 1/8 G2 LTO-3 Ultrium 920 SAS Autoloader | AH558A | |
| Tape Libraries | ||
| HP StorageWorks MSL2024 1 LTO-4 Ultrium 1760 SAS Drive Library | AK378A | |
| HP StorageWorks MSL2024 1 LTO-3 Ultrium 920 SAS Drive Library | AH559A | |
| HP StorageWorks MSL4048 1 LTO-4 Ultrium 1760 SAS Drive Library | AK380A | |
| HP StorageWorks MSL4048 1 LTO-3 Ultrium 920 SAS Drive Library | AH560A | |
| HP StorageWorks MSL8096 2 LTO-4 Ultrium 1760 SAS Drive Library | AK382A | |
| HP StorageWorks MSL8096 2 LTO-3 Ultrium 920 SAS Drive Library | AH561A | |
| SAS Cables for Tape Drives | ||
| 2M External Mini-SAS (SFF8088)
to Mini-SAS (SFF8088) 1x SAS Cable NOTE: Use this cable to connect HP StorageWorks SAS external tape devices to HP SAS controllers with external Mini-SAS (SFF8088) connectors. |
AE470A | |
| 4M External Mini-SAS (SFF8088)
to Mini-SAS (SFF8088) 1x SAS Cable NOTE: Use this cable to connect HP StorageWorks SAS external tape devices to HP SAS controllers with external Mini-SAS (SFF8088) connectors. |
AE465A | |
| 2M External Mini-SAS (SFF8088)
1x to Mini-SAS (SFF8088) 4x fanout SAS Cable NOTE: Use this cable to connect HP StorageWorks MSL SAS Tape Libraries to Mini-SAS (SFF8088) ports. |
AN975A | |
| 4M External Mini-SAS (SFF8088)
1x to Mini-SAS (SFF8088) 4x fanout SAS Cable NOTE: Use this cable to connect HP StorageWorks MSL SAS Tape Libraries to Mini-SAS (SFF8088) ports. |
AN976A | |
|
|
||
| SAS to Mini SAS Cables | Mini-SAS to Mini-SAS, 8.00" | 496012-B21 |
| Mini-SAS to Mini-SAS, 25.50" & 28.00" | 496013-B21 | |
| Mini-SAS to Mini-SAS, 33.00" | 496014-B21 | |
| Mini-SAS to SFF8484, 18.00" | 496015-B21 | |
| Mini-SAS to SFF8484, 24.00" | 496015-B21 | |
| Mini-SAS to SFF8484, 32.00" | 496016-B21 | |
| Mini-SAS to SFF8484, 35.00" | 496016-B21 | |
| Mini-SAS to SFF8484, 33.00" | 591734-B21 | |
|
|
||
| Additional Cables | HP 15 POS 24in SFP Battery Cable Assy | 496029-B21 |
|
|
Technical Specifications
| Dimensions (excluding bracket) | Low Profile PCIe Form Factor 19.05 cm x 24.13 cm x 5.72 cm (7.5 in x 9.5 in x 2.25 in) |
| Disk Drive and Enclosure Protocol Support - Transfer rate | 6Gb/s SAS (Serial Attached SCSI) |
| 3Gb/s SATA (Serial AT Attachment) | |
| SAS Connectors | 2 external (Mini SAS) x8 wide port connectors |
| Data Transfer Method | x8 5G PCIe 2.0 Express (4 GB/s maximum bandwidth) |
| Memory Bus Speed | DDR2-800 MHz with 40 bit or 72-bit wide bus provides up to 4.2 GB/s maximum bandwidth |
| PCI | PCIe Express Gen 2.0 |
| Simultaneous Drive Transfer Ports | 2 x4 Wide SAS Ports |
| SAS Port Link Rate | 24 Gb/s per x4 wide port connector (4 x 6 Gb/s) |
| Software upgradeable Firmware | Yes |
| Cache Memory | 40-bit 256 MB Read/Write ECC protected cache (72-bit 512MB BBWC upgrade available); transportable with battery backed upgrade |
| Logical Drives Supported | Up to 64 logical drives |
| Maximum Capacity | 100TB (100 x 1TB) NOTE: Support for greater than 2TB in a single logical drive. |
| Memory Addressing | 64-bit, supporting servers memory space greater than 4 GB |
| RAID Support |
RAID 6, 6+0 (Advanced Data Guarding)
RAID 5, 5+0 (Distributed Data Guarding) |
| Upgradeable Firmware | Upgradeable Firmware with Recovery ROM feature |
|
|
|
| Environment-friendly Products and Approach | End-of-life Management and Recycling | Hewlett-Packard offers end-of-life HP product
return, trade-in, and recycling programs in many geographic areas. For trade-in
information, please go to: http://www.hp.com/go/green.
To recycle your product, please go to: http://www.hp.com/go/green
or contact your nearest HP sales office. Products returned to HP will be
recycled, recovered or disposed of in a responsible manner. The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett Packard web site at: http://www.hp.com/go/green. These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re-sell HP equipment. |
| | ||
|
© Copyright 2009 Hewlett-Packard Development Company, L.P. |