contents.gif (598 bytes)
spacer.gif (818 bytes)
arrow.gif (58 bytes) Overview
arrow.gif (58 bytes) Standard Features
arrow.gif (58 bytes) Systems/Options
arrow.gif (58 bytes) Options
arrow.gif (58 bytes) Power Configuration Table
arrow.gif (58 bytes) Upgrades
arrow.gif (58 bytes) TechSpecs
spacerw.gif (802 bytes) QuickSpecs

Compaq AlphaServer GS140

GS60E.jpg (46916 bytes)

  1. CD-ROM with space for
    optional diskette drive
  2. Cabinet Control System
  3. 9-Slot System Bus
    (four front, five rear)
  4. Power System
  5. Cooling
  6. Plug-In Units/ I/O or Disks or (two
    front, two rear)

At A Glance
AlphaServer GS140 Systems include:

  • Processor module with two Alpha 21264A 6/700-MHz CPUs, each with 8-MB backup cache
  • System I/O module with four
    I/O channels
  • 4-GB memory
  • UltraSCSI single-channel StorageWorks Plug-in Unit
  • 9.1-GB 3.5² UltraSCSI system disk drive
  • 2-m SCSI cable, BN38C-02
  • 600-MB CD-ROM drive, controller, and cable
  • 12-slot PCI Plug-in-Unit
  • PCI 1-port UltraSCSI Single-ended adapter
  • 10/100 Mb Fast Ethernet network interface card
  • Two H7263-AC or H7263-AD non-BBU capable 48 VDC power regulators.
  • 3-phase power subsystem with power cord
  • Shielded console cable for connection to terminal
  • Tru64™ UNIX or OpenVMS Factory Installed Software
  • 90-day software product warranty
  • Protected by Compaq Services, including a one-year, on-site, four-hour response hardware warranty; system installation must be ordered separately

contents.gif (598 bytes)
spacer.gif (818 bytes)
arrow.gif (58 bytes) Overview
arrow.gif (58 bytes) Standard Features
arrow.gif (58 bytes) Systems/Options
arrow.gif (58 bytes) Options
arrow.gif (58 bytes) Power Configuration Table
arrow.gif (58 bytes) Upgrades
arrow.gif (58 bytes) TechSpecs
Standard Features
Processor
Two Alpha 21264A 6/700-MHz processors (two CPUs per module)
Cache Memory
8-MB ECC L2 onboard cache per 6/700-MHz CPU
Architecture
64-bit bus-based system architecture with nine system bus slots for CPU, memory, and I/O modules
(1.87-GB/second sustained system bandwidth, 2.1-GB/second peak bandwidth)
Upgradability
In-cabinet upgrades support additional processors, additional memory, additional I/O port modules, as well as storage and PCI I/O module options; upgrades available to next generation Alpha GS Series systems
Standard 2 CPUs on one CPU module
Maximum 14 (seven dual-CPUs)
System I/O Module and System I/O Expansion
System I/O module with four I/O channels (KFTHA-AA)
Standard 1
Maximum 3
PCI Plug-in Unit (DWLPB-AA) with 12-slot PCI box and space for second 12-slot PCI box or StorageWorks shelf
Standard 1
Maximum 12
Memory
Standard 4 GB
Maximum 28 GB
Network Controller
PCI 10/100 Mb Fast Ethernet adapter UTP
Expansion
Drive Bays 7 to 49 available in system cabinet; up to 84 available in I/O expansion cabinet
PCI 144 slots
Storage
CD-ROM 5.25² half height CD-ROM drive
Hard Drive 9.1-GB UltraSCSI disk drive (standard) ); 18.2-GB and 36.4-GB drives available
Maximum Internal Storage 1784 GB (36.4-GB drives)
Storage Controller
UltraSCSI Fast Wide Single-ended adapter
Power
3-phase power subsystem with power cord
Optional standalone UPS with added backup runtime for systems and external devices available
Intelligent Manageability
Compaq Insight Manager
Security
Chassis lock
Multi-boot for choice of boot device
OS Support
AlphaServer GS140 Tru64 UNIX systems include pre-installed software, Base license, Unlimited User license, Server Extension license, Open Source Internet Solutions, and iPlanet Web Server – Enterprise Edition 4.0.
AlphaServer GS140 OpenVMS systems include pre-installed software, Base license and Enterprise Integration Server License Package V3.0A.
Support is available for up to three instances of either Tru64 UNIX or OpenVMS on a single hardware platform.
OS support: Tru64 UNIX V4.0E, V4.0F, V4.0G, V5.0, V5.0A or later or OpenVMS V7.1-2 or V7.2-1 or later
Service and Support
Protected by Compaq Services, including one-year, on-site hardware warranty with four-hour response. Software warranty is a 90-day telephone advisory. Training, consulting, network integration, software support, comprehensive system maintenance and guaranteed uptime services are also available for customers requiring higher levels of service and support.

contents.gif (598 bytes)
spacer.gif (818 bytes)
arrow.gif (58 bytes) Overview
arrow.gif (58 bytes) Standard Features
arrow.gif (58 bytes) Systems/Options
arrow.gif (58 bytes) Options
arrow.gif (58 bytes) Power Configuration Table
arrow.gif (58 bytes) Upgrades
arrow.gif (58 bytes) TechSpecs
Systems/Options
Step 1 - Select system
AlphaServer GS140 systems require the mandatory selection of the following items:
  • Software media and documentation for first system on-site
  • Console terminal (unless available on site)
  • Installation or Installation and Startup Services

Notes: Minimum OS support: Tru64 UNIX V4.0E or later or OpenVMS V7.1-2 or V7.2-1 or later
For system integration of any options with 6-3 part numbers, contact CustomSystems

OS

CPUs

Memory

UltraSCSI Disk

UltraSCSI Adapter

Ethernet Adapter

Order No.

Tru64 UNIX

Two 6/700 MHz

4 GB

9.1 GB

KZPBA-CA

DE500-BA or
3X-DE600-AA

DA-394GG-AA/AB/AC

Open
VMS

Two 6/700 MHz

4 GB

9.1 GB

KZPBA-CA

DE500-BA or
3X-DE600-AA

DY-394GG-AA/AB/AC

Note: AA=60 Hz, 208V; AB=50 Hz, 416V; AC=50/60 Hz, 202V (Japan)
Step 2 - Additional CPU Modules (SMP Expansion) - Optional
  • Maximum of seven processor modules (14 CPUs)
  • All CPU modules must be at same speed on same bus.
  • For systems with more than three processor modules, a minimum of two memory modules is recommended for optimal system performance
  • SMP license and end-user product warranty included
  • To order a system with added CPUs for future expansion, refer to the Compaq Capacity on Demand (CCoD) Program described in the "Upgrades" section
GS140 6/700 Tru64 UNIX SMP upgrade

3X-764P2-AX

GS140 6/700 OpenVMS SMP upgrade

3X-764P1-AX

Step 3 - Memory - Optional
  • Maximum 28-GB memory, maximum seven memory modules (maximum of seven memory modules is reduced by one for each additional CPU module and System I/O module added).
  • Both 1-GB and 2-GB memory modules have built-in, 2-way interleaving; additional interleaving is accomplished by adding more memory modules.
  • 4-GB memory modules have built-in, 4-way interleaving; optimum performance is achieved when 2-GB memory modules are paired with one 4-GB module or one 4-GB memory module is paired with another 4-GB module. Memory module sets (2 GB x 2 GB and 1 GB x 4 GB) or (2 GB x 4 GB) can be paired with another
    8-GB memory set for a maximum of 16-way memory interleaving.
4-GB memory module

MS7CC-GA

2-GB memory module

MS7CC-FA

1-GB memory module

MS7CC-EA


contents.gif (598 bytes)
spacer.gif (818 bytes)
arrow.gif (58 bytes) Overview
arrow.gif (58 bytes) Standard Features
arrow.gif (58 bytes) Systems/Options
arrow.gif (58 bytes) Options
arrow.gif (58 bytes) Power Configuration Table
arrow.gif (58 bytes) Upgrades
arrow.gif (58 bytes) TechSpecs
Options
Step 4 - I/O Expansion Buses - Optional
  • Systems include one PCI Plug-in Unit (PIU) DWLPB-AA, maximum two supported in system cabinet
  • Each DWLPB-AA PCI PIU includes 12-slot PCI bus and uses one rear expansion bay; StorageWorks BA670 PIU can occupy the corresponding front expansion bay.
  • Each DWLPB-AA PCI PIU has one open space for the addition of DWLPB-BA (second PCI expansion box) or one BA671 Wide-UltraSCSI StorageWorks shelf
  • Each PCI Plug-in Unit requires one I/O channel connection to KFTHA-AA
  • Tru64 UNIX and OpenVMS systems support a maximum of 12 I/O channels with up to three KFTHAs
Note: DWLPAs are not supported on GS140 systems and upgrades.
PCI Plug-in-Unit with one PCI box for GS140 system cabinet only; requires one I/O channel connection on KFTHA-AA, maximum two per system cabinet, two per system

DWLPB-AA

Second PCI expansion box for mounting in DWLPB-AA; requires one I/O channel connection on
KFTHA-AA, maximum one per DWLPB-AA

DWLPB-BA

Note: KFE70-AA and KFE72-EA are not supported concurrently on same system; however, either option can be used to run RAID Configuration Utility (RCU).
UltraSCSI Single Channel StorageWorks Shelf (DS-BA356-LE) can be added to DWLPB-AA/AB in place of second PCI expansion box (DWLPB-BA/BB); supports 16-bit (Wide) SCSI and some 8-bit (Narrow) SCSI devices; maximum one per DWLPB-AA/AB, maximum six per system

BA671-AA

UltraSCSI Dual Channel StorageWorks Shelf (DS-BA356-LF) can be added to DWLPB-AA/AB in place of second PCI expansion box (DWLPB-BA/BB); supports 16-bit (Wide) SCSI and some 8-bit (Narrow) SCSI devices; maximum one per DWLPB-AA/AB, maximum six per system

BA671-AB

Step 5 - System I/O Modules - Optional
  • KFTHA-AA system I/O module included with systems; two additional KFTHA I/O modules can be added for a system maximum of three
System I/O module with four I/O channels for PCI Plug-in Unit

KFTHA-AA

Step 6 - Storage Adapters/Controllers - Optional
  • Tru64 UNIX V4.0B without VGA support, or V4.0D or later with VGA, supports eight SCSI controllers per PCI, maximum 64 per system.
  • OpenVMS V6.2-1H3 or later supports eight SCSI controllers per PCI, maximum 26 per system
  • For maximum controllers per PCI, required System Console Firmware Revision is 5.2-7 or later for 8400, or
    5.3-12 or later for GS140
  • PCI controllers can be added to all systems
  • Requires corresponding PCI Plug-in Unit (DWLPB-AA/AB/BA/BB)
  • System maximum of four KZPAC SCSI RAID controllers
  • Tape and optical devices are not supported on KZPAC SCSI RAID controllers.
  • Order Rear Door Expansion Kit, H9FDK-BA (top gun blue), for cable management on systems configured with more than 12 SCSI controllers.
  • For cluster configurations, use Y cable (BN39A-0G) or SCSI Hub (BA35X-03/05)
  • DS-BA35X-DA UltraSCSI personality module required to connect DS-BA356-LE StorageWorks Shelf to a KZPSA-BB or KZPBA-CB Differential SCSI adapter
  • OpenVMS V7.1-1H1 or later supports multi-host SCSI clusters
  • Manufacturing may substitute correct cable length depending on configuration
  • OpenVMS systems with greater than 1-GB memory require the following TIMA patch kits to support KZPAC options: V6.2 kit-ALPDRIV04_062 and V7.1 kit-ALPDRIV01_071
Note: For installed systems that include KFTIA I/O modules, the KFTIA includes one single-ended port and three fast wide differential ports for a total of four SCSI buses per module.
 

Maximum # Supported

 

Tru64 UNIX

Open
VMS

PCI/
System

PCI/
System

PCI Fibre Channel adapter (DS-KGPSA-CA) (uses one PCI slot); requires Tru64 V4.0F (maximum 62) or V5.0A (maximum 63) or OpenVMS V7.2-1; requires Fibre Channel cable. (DS-KGPSA-CA adapter is used with HSG60 and HSG80 Fibre Channel controllers.) FC-AL is not supported on these platforms. For best performance, configure up to three Fibre Channel adapters per DWLPB, one per segment. For most connections, configure up to eight per DWLPB – no segment restrictions.

8/63

8/8

168794-B21

Fibre Channel cable (BNGBX-xx) xx=02, 05, 15, 30, 50 meters
x=1, 2, 3, 4, 5
 

234457-B2x

PCI Fibre Channel tape controller (SCSI-to-Fibre), 1 Fibre x 1 SCSI, GLM  

340654-001

PCI Fibre Channel tape controller (SCSI-to-Fibre), 1 Fibre x 2 SCSI, GBIC  

152975-001

Note: Complete cluster support available only with Veritias Net Backup
  
PCI 1-port UltraSCSI single-ended adapter (uses one PCI slot)

8/64

8/26

KZPBA-CA

PCI 1-port UltraSCSI differential host adapter (uses one PCI slot)

8/64

8/26

KZPBA-CB

1-m VHDCI male-to-68 pin HD male UltraSCSI cable, connects KZPBA-Cx to BA670 in system cabinet (rear)  

BN38C-01

2-m VHDCI male-to-68 pin HD male UltraSCSI cable, connects KZPBA-Cx to BA670 in system cabinet (front)  

BN38C-02

3-m VHDCI male-to-68 pin HD male UltraSCSI cable, connects KZPBA to I/O expansion cabinet  

BN38C-03

5-m VHDCI male-to-68 pin HD male UltraSCSI cable, connects KZPBA to I/O expansion cabinet  

BN38C-05

  
PCI 1-port RAID (FWSE) controller (UltraSCSI-ready) with 4-MB cache memory (uses one PCI slot); allows RAID levels 0, 0+1, 1, 5; includes RAID Array 230/plus subsystem software and documentation kit; EISA bridge option with floppy diskette drive required to run RCU; tape and optical drives not supported

4/4

4/4

KZPAC-AA

PCI 3-port RAID (FWSE) controller (UltraSCSI-ready) with 4-MB cache memory (uses two PCI slots); allows RAID levels 0, 0+1, 1, 5; includes RAID/Array 230/plus subsystem software and documentation kit; EISA bridge option with floppy diskette drive required to run RCU; tape and optical drives not supported; requires BN31K-0E or KZPAC-SB for third-port connection

4/4

4/4

KZPAC-CA

PCI 3-port RAID (FWSE) controller (UltraSCSI-ready) with 8-MB cache memory (uses two PCI slots); allows RAID levels 0, 0+1, 1, 5; includes RAID/Array 230/plus subsystem software and documentation kit; EISA bridge option with floppy diskette drive required to run RCU; tape and optical drives not supported; requires BN31K-0E or KZPAC-SB for third-port connection

4/4

4/4

KZPAC-CB

SCSI cable/bulkhead assembly kit with two ports for KZPAC-CA/CB, allows connection of two third port outputs using one PCI bulkhead slot  

KZPAC-SB

SCSI cable/bulkhead assembly kit with one port for KZPAC-CA/CB, allows connection of one third port output using one PCI bulkhead slot  

BN31K-0E

1-m VHDCI male-to-VHDCI male UltraSCSI cable, connects KZPAC to rear-mounted StorageWorks shelf  

BN37A-01

2-m VHDCI male-to-VHDCI male UltraSCSI cable, connects KZPAC to front-mounted StorageWorks shelf  

BN37A-02

Battery backup for cache memory option for KZPAC controller, recommended for all KZPAC controllers  

KZPSC-UB

8-MB cache memory option; upgrades KZPAC-CA to KZPAC-CB, field installable only  

MS100-BB

 
PCI Fast Wide Differential SCSI Adapter (uses one PCI slot); KZPSA supports TruCluster Available Server and TruCluster Production Server

8/64

8/26

KZPSA-BB

SCSI-2 Fast Wide Differential cables; 68-pin male straight-to-68-pin male right-angle; connects KZPSA-BB Fast Wide Differential SCSI-2 port to DWZZA-VA or DWZZB-VW or connects to DOC-based BA356 via BN38C cables to gain additional slot  

BN21K-xx

Connects from KZPSA to DWZZB-VW in BA670-AB System cabinet (rear);
connects from KZPSA to DWZZB-VW in BA671-AA in DWLPB-xx PIU
 

BN21K-01

Connects from KZPSA to DWZZB-VW in BA670-AB System cabinet (front)  

BN21K-02

Connects from KZPSA to DWZZB-VW in BA670-AB Expansion cabinet
(front or rear)
 

BN21K-05/10

 
PCI CI adapter (uses one PCI slot for adapter and one EISA slot for power only); EISA Bridge option not required

-

4/26

CIPCA-AA

Same as CIPCA-AA except uses 2 PCI slots

-

4/26

CIPCA-BA

Computer interconnect cable sets, connects CIPCA to Star Coupler; select length—10, 20, or 45 m  

BNCIA-xx

Step 7 - External Storage Controllers - Optional
  • HSZ80 UltraSCSI RAID Array controllers require Tru64 UNIX V4.0E or later or OpenVMS V7.1-2 or later
  • HSG80 Fibre Channel controllers are supported under Tru64 UNIX V4.0F or later or OpenVMS V7.2-1 or later
  • HSG60 Fibre Channel controllers require Tru64 UNIX V4.0F or later or OpenVMS V7.2-1 or later (standalone and cluster support); order one HSG60 ACS Software Kit per HSG60
  • HSJ50 CI Storage Array Controllers are supported under OpenVMS V6.2-1H3 or later with CIPCA-AA/BA or
    CIXCD-AC CI controllers; QB-5C4AA-SA software kits are required for each external cache (one for HSJ50, two for HSJ52, four for HSJ54).
  • Controllers require KZPSA, KZPBA, KFPSA, CIXCD or CIPCA SCSI adapters or controllers, as appropriate
Fibre Channel controller (HSG80), includes 256-MB cache expandable to 512-MB; requires
128697-B21 HSG80 ACS V8.4F software kit or 128698-B21 V8.4P software kit for each
HSG80 ordered

380672-B21

Fibre Channel controller (HSG60) includes 256-MB cache expandable to 512-MB; requires
180319-B21 HSG60 ACS V8.5L software kit (QB-6FTAA-SA) for each HSG60 ordered

174134-B21

HSG60 Tru64 UNIX Software Kit (QB-6J4AB-SA)

192211-B21

HSG60 OpenVMS Software Kit (QB-6J4AC-SA)

192217-B21

256-MB Cache Option for HSG60 (DS-HSD1M-AC)

380674-B21

UltraSCSI controller (HSZ80), includes 64-MB cache expandable to 128 MB, requires 400569-001 for Tru64 UNIX or 400571-001 for OpenVMS

400564-B21

UltraSCSI controller (HSZ80), includes 256-MB cache expandable to 512 MB, requires 400569-001 for Tru64 UNIX or 400571-001 for OpenVMS

400565-B21

32-MB cache 6-channel CI array controller with cache battery

HSJ50-AF

64-MB cache 6-channel CI array controller with cache battery

HSJ50-AH

128-MB cache 6-channel CI array controller with cache battery

HSJ50-AJ

Dual 64-MB cache CI array controller with cache batteries

HSJ52-AF

Dual 128-MB cache CI array controller with cache batteries

HSJ52-AH

Dual 256-MB cache CI array controller with cache batteries

HSJ52-AJ

Quad 512-MB cache CI array controller with cache batteries

HSJ54-AJ

Step 8 - Storage Devices - Optional
  • When multiple storage devices are configured with the system, specify which devices should be installed inside system cabinet, inside system expansion cabinet, or installed in external StorageWorks cabinet. Line item sequencing allows Manufacturing to configure storage options in the appropriate cabinet.
  • List storage options to be integrated in system cabinet immediately following the system part number.
  • List storage options to be integrated in StorageWorks cabinet immediately following StorageWorks cabinet part number.
Internal Storage
  • System cabinet provides space for four disk Plug-in Units (PIU) if no PCI Plug-in Units are installed. Each of the two pairs of expansion bays (front-to-back) in bottom of system cabinet can hold one Battery PIU, one PCI PIU plus one SCSI disk PIU, one SCSI disk PIU, or two SCSI disk PIUs.
  • System cabinet provides space for up to seven StorageWorks shelves— three BA670-AB Plug-in Units (each includes two StorageWorks shelves) and one BA671-AA StorageWorks shelf mounted in a DWLPB; each shelf holds a maximum of two 5.25² devices and one 3.5² device or seven 3.5² devices
  • UltraSCSI devices are supported in UltraSCSI StorageWorks PIUs and UltraSCSI StorageWorks shelves; BA670-Ax and BA671-Ax support wide and narrow SCSI 5400 rpm, 7200 rpm, and 10,000 rpm disk drives
  • Order appropriate BN21*-** SCSI cables for connecting controllers and SCSI storage options.
  • Refer to the UltraSCSI Configuration Guidelines (EK-ULTRA-CG.C01)
UltraSCSI StorageWorks Plug-in Units
UltraSCSI single-channel StorageWorks Plug-in Unit, includes two DS-BA356-LE modular expansion shelves, 16-bit single-ended I/O personality module (DS-BA35X-FA), single-channel I/O module, 48V 150W DC power supply, and GS140 mounting hardware; supports 16-bit wide SCSI devices and some 8-bit narrow SCSI devices depending on compliance with minimum hardware revision levels (included with base systems)

BA670-AA

UltraSCSI dual-channel StorageWorks Plug-in Unit, includes two DS-BA356-LF modular expansion shelves, 16-bit single-ended I/O personality module (DS-BA35X-FB), dual-channel I/O module, 48V 150W DC power supply, and GS140 mounting hardware; supports 16-bit wide SCSI devices and some 8-bit narrow SCSI devices depending on compliance with minimum hardware revision levels

BA670-AB

UltraSCSI StorageWorks Shelves
UltraSCSI single-channel StorageWorks Shelf, includes 16-bit single-ended I/O personality module (DS-BA35X-FA), single-channel I/O module, 48V 150W DC power supply, mounting hardware and DS-BA356-LE.; can be added to DWLPB-AA/AB in place of second PCI expansion box
(DWLPB-BA/BB); supports 16-bit (wide) SCSI and some 8-bit (narrow) SCSI devices; maximum one per DWLPB-AA/AB; maximum six per system

BA671-AA

UltraSCSI dual-channel StorageWorks Shelf, includes 16-bit single-ended I/O personality module
(DS-BA35X-FB), dual-channel I/O module, 48V 150W DC power supply, mounting hardware and DS-BA356-LF.; can be added to DWLPB-AA/AB in place of second PCI expansion box (DWLPB-BA/BB); supports 16-bit (wide) SCSI and some 8-bit (narrow) SCSI devices; maximum one per DWLPB-AA/AB; maximum six per system

BA671-AB

SCSI Signal Converter
UltraSCSI-2 StorageWorks DOC Signal Converter, required to convert FWD signals from KZPSA-BB or KZPBA-CB to single-ended for connection to DS-BA356-LE/LF StorageWorks shelves, field installed only- DOC card installed in shelf does not utilize drive slot

DS-BA35X-DA

Fast20 Personality Module for BA356 single-ended-to-single-ended 1-channel, field installed only

DS-BA35X-FA

Fast20 Personality Module for BA356 single-ended-to-single-ended 2-channel, field installed only

DS-BA35X-FB

Cable for above

BN38C-02

UltraSCSI Hubs
UltraSCSI Hub with three differential ports (two host ports and one storage port), no single-ended ports, in 3.5² SBB, UltraSCSI cables not included

DS-DWZZH-03

UltraSCSI Hub with five differential ports, no single-ended ports, consisting of four host ports and one storage port in a 5.25² SBB, UltraSCSI cables not included

DS-DWZZH-05

UltraSCSI Hub with one differential port and two single-ended ports in 3.5² SBB, UltraSCSI cables not included

DS-DWZZH-21

16-bit Disk Drives
  • For 10,000 rpm drives, maximum six 18-GB or larger capacity drives when used in any BA356 blue shelf; 5.25" devices not supported on same bus
Note: UltraSCSI disk drives run in Fast10 SCSI mode with KZPSA-BB PCI Fast Wide Differential SCSI adapters or Fast20 mode with KZPBA or KZPAC adapters
36.4-GB 10,000 rpm 16-bit UltraSCSI disk drive SBB (not supported on KZPAC controllers)

DS-RZ1FC-VW

18.2-GB 10,000 rpm 16-bit UltraSCSI disk drive SBB (not supported on KZPAC controllers)

DS-RZ1ED-VW

18.2-GB 7,200 rpm 16-bit UltraSCSI disk drive SBB (not supported on KZPAC controllers)

DS-RZ1EA-VW

9.1-GB 10,000 rpm 16-bit UltraSCSI disk drive SBB

DS-RZ1DD-VW

9.1-GB 7,200 rpm 16-bit UltraSCSI disk drive SBB

DS-RZ1DA-VW

Tape Drives
  • Tape drives not supported with KZPAC RAID controller
8-GB DAT 3.5² SCSI tape drive in StorageWorks carrier; requires OpenVMS V6.2-1H3 or later or Tru64 UNIX V3.2C or later and System Console Firmware Revision 3.0-9

TLZ09-VA

32/64-GB DAT tape loader in StorageWorks carrier

TLZ9L-VA

12/24-GB 4mm DAT SCSI tape drive in StorageWorks carrier

DS-TLZ10-VA

20/40-GB DLT SCSI tape drive in 5.25² StorageWorks carrier

TZ88N-VA

35/70-GB DLT SCSI tape drive in 5.25² StorageWorks carrier

DS-TZ89N-VW

40/80-GB DLT SCSI tape drive in 5.25² StorageWorks carrier; requires Tru64 UNIX V4.0F, TruCluster V1.5 or OpenVMS V7.1 or later

DS-TZ90N-VW

Solid State Disks
  • Supported with KZPBA and KZPSA adapters
  • Solid state disks cannot be combined with RZxx disks/tapes on same SCSI bus.
  • 3.5² and 5.25² solid state disks not supported on same SCSI bus
1.6-GB Fast20 5.25² Ultra solid state disk

DS-EZ716-VW

RAID Storage Solutions
  • ESA 12000 Storage Arrays and RAID Array 8000 (HSG80/HSZ80) product sets are supported on Tru64 UNIX and OpenVMS systems.
  • ESA 10000 Storage Arrays and RAID Array 7000 (HSZ70) product set are supported on Tru64 UNIX and
    OpenVMS systems.
  • Ordering and configuring information is available at www.compaq.com/products/storageworks
External Storage Devices
The following devices can be added as required:
SW5XX, SW6XX, SW8XX Storage Cabinets
SCSI Disk Drives
Tape Drives - TZ87, TZ857 (loader support for Tru64 UNIX available via DECnsr), TZ877, TZ88, TZ885, TZ887, TSZ07, TLZ09, TKZ9E, TKZ9F, TLZ9L, TKZ6x, TL810, TL812, TL820, TL822, TL826, DS-TL891-NE/NT,
DS-TL892-UA, DS-TL893-BA/AC, DS-TL894-BA, DS-TL896-BA, DS-TLZ10-VA, DS-TL895-xx, TZK10/12/20
Step 9 - Networks and Communications - Optional
  • Connection of system to Ethernet requires twisted-pair cable (except when using DE500-FA).
Note: For installed systems with KFTIA I/O modules, KFTIA includes two 802.3/Ethernet ports per module.
PCI LAN Communications Controllers
  • Requires DWLPB-xx PCI shelf mount box (one included)
  • Maximum six 3X-DEFPA-AC/DC/UC/MC FDDI controllers (100 Mb/sec) per system
  • Each adapter/controller uses one PCI slot
 

Maximum # Supported

 

Tru64 UNIX

Open
VMS

PCI/
System

PCI/
System

Universal PCI to FDDI controller Fibre, Single Attachment Station (SAS) MultiMode Fibre with SC; requires BN34x SC type connecting cable

6

6

3X-DEFPA-AC

Universal PCI to FDDI controller Fibre, Dual Attachment Station (DAS) MultiMode Fibre with SC; requires BN34x SC type connecting cable

6

6

3X-DEFPA-DC

MultiMode Fibre Optic Duplex cable; SC connector-to-ST connector  

BN34A-xx

MultiMode Fibre Optic Duplex cable; SC connector-to-SC connector  

BN34B-xx

MultiMode Fibre Optic Duplex cable; SC connector-to-MIC connector  

BN34D-xx

 
Universal PCI to FDDI controller, copper, Dual Attachment Station (DAS) CAT 5 UTP with RJ; requires BN26x or BN25H connecting cables

6

6

3X-DEFPA-MC

Universal PCI to FDDI controller copper, Single Attachment Station (SAS) CAT 5 UTP with RJ; requires BN26x or BN25H connecting cables

6

6

3X-DEFPA-UC

8-pin MP-to-8-pin MP, screened, EIA/TIA category 5 cable  

BN26M-xx

8-pin MP-to-8-pin MP, screened, crossover, EIA/TIA category 5 cable  

BN26S-xx

3-m unshielded twisted pair RJ45 connectors  

BN25H-03

 
PCI 1-port 10/100-Mb Ethernet adapter (Twisted Pair); SN-PBXNP-AC (Token Ring Adapter) not supported in same system; requires NHD1 of Tru64 UNIX (UCX V4.2 TCP/IP Services Software not recommended with DE60* devices; TCP/IP V5.0 is recommended)

8/8

8/8

3X-DE600-AA

Category 5 cross-over cable for point-to-point, unshielded  

BN24Q-xx

Category 5 cross-over cable for point-to-point, shielded  

BN28Q-03

Category 5 straight through for system to repeater or hub, unshielded  

BN25G-xx

Twisted pair, shielded (-03, -04, -07 available lengths)  

BN26M-xx

 
PCI Gigabit Ethernet adapter, does not support network boot; one
per DWLPB

1/4

1/4

DEGPA-SA

PCI-to-ATMworks 155 Mb fibre adapter; Tru64 UNIX and appropriate patch kits (patch kit 1 for V4.0F; patch kit 2 for V4.0E, patch kit 4 for V4.0D); refer to http://www.service.digital.com for patch kit availability; SN-PBXNP-AC PCI Token Ring adapter not supported in same system with ATM 155 (DAPBA) adapter; if ATMworks 351 (DGLPA) NIC card is installed, follow that adapter’s configuration rules; only one ATM adapter can be installed on same bus as ATMworks 351 network interface card.

6

-

3X-DAPBA-FA

Same as above except UTP  

3X-DAPBA-UA

PCI-to-ATMworks 622 Mb fibre adapter; Tru64 UNIX and appropriate patch kits (patch kit 1 for V4.0F; patch kit 2 for V4.0E, patch kit 4 for V4.0D); refer to http://www.service.digital.com for patch kit availability; SN-PBXNP-AC PCI Token Ring adapter not supported in same system with ATM 622 (DAPCA) adapter; if ATMworks 351 (DGLPA) NIC card is installed, follow that adapter’s configuration rules; only one ATM adapter can be installed on same bus as ATMworks 351 network interface card.

1/2

-

3X-DAPCA-FA

  
PCI Asynchronous 4-port adapter, maximum two PBXDA-xx per system

2/2

2/2

PBXDA-AA

PCI Asynchronous 8-port adapter, maximum two PBXDA-xx per system

2/2

2/2

PBXDA-AB

PCI Asynchronous 16-port adapter, maximum two PBXDA-xx
per system

2/2

2/2

PBXDA-AC

PCI Synchronous 2-port controller, two PBXDP-xx per system; requires OpenVMS V7.1-2 or Tru64 UNIX V4.0F or V5.0A or later

2/2

2/2

PBXDP-AA

PCI Synchronous 4-port controller, two PBXDP-xx per system; requires OpenVMS V7.1-2 or Tru64 UNIX V4.0x or V5.0A or later

2/2

2/2

PBXDP-AB

Note: PBXDP-AA/AB options require WAN 3.1A kit for Tru64 UNIX V5.0A or later ? QA-045AA-H8 or QT-045AA-C8
Step 10 - MEMORY CHANNEL - Optional
  • MEMORY CHANNEL options are supported on GS140 with Console Firmware V5.3-12 or later and 8400 systems with Console Firmware V5.4-10 or later; Console Firmware is available on CD-ROM (AG-RFCBB-BE) and the following Web site: http://ftp.digital.com/pub/Digital/Alpha/firmware/interim
    /gs60gs140
  • Two PCI System Area Network controllers supported per system
  • The following options are not currently supported with MEMORY CHANNEL: DJ-ML200, CIPCA
Tru64 UNIX Systems (V5.0A and later)
  • Each system node in the cluster requires a TruCluster Server license (QL-6BRAQ-AA)
Tru64 UNIX Systems (V4.0F or V4.0G)
  • Requires a minimum of Tru64 UNIX V4.0F with TruCluster V1.6 or later
  • Each system node in a MEMORY CHANNEL cluster requires a TruCluster Production Server (QB-3RLAQ-AA) or TruCluster MEMORY CHANNEL (QB-4ZCAQ-AA) software license
  • TruCluster MEMORY CHANNEL license (QB-4ZCAQ-AA), normally used for high- performance technical computing applications, is not required if systems include a TruCluster Production Server license (QB-3RLAQ-AA)
Open VMS Systems
  • MEMORY CHANNEL options require OpenVMS V7.1-2 or later and OpenVMS Cluster license (QL-MUZAQ-AA)
MEMORY CHANNEL Controller/Network Hub
  • Two-node clusters can be configured by ordering a CCMAB-AA for each system and 1 BN39B-04 or BN39B-10 cable, cable connects directly to CCMAB-AA in each system
  • For three or four system clusters, order one CCMAB-AA adapter and one BN39B-04 or BN39B-10 cable for each system and one CCMHB-AA hub for the cluster
  • CCMHB-AA includes four CCMLB-AA line cards and supports up to four nodes; expansion up to eight system nodes can be achieved by adding up to four additional CCMLB-AA line cards
  • If two or more CCMAB-AA controllers are configured in each system, a second CCMHB-AA hub is required for clusters with more than two nodes in two-node clusters the CCMAB-AA may be directly connected.
  • In cases where nodes must be separated by a longer distance than standard copper cables allow, the CCMFB option converts the output of the standard CCMAB controller or CCMLB line card to single-mode fibre optic cable. The fibre optic connection may be up to 2,000 meters long between two CCMAB controllers connected in virtual hub mode, or 3,000 meters between a CCMAB controller and a CCMHB hub. (The connection from the CCMHB hub to a second system may also be 3,000 meters). The CCMFB option requires a second PCI slot in the system from which it draws power only. It is normally connected to the corresponding CCMAB controller with the short BN39B-01 cable. The CCMFB is also used in the CCMHB hub where it occupies a slot normally used by the CCMLB line card, limiting expansion to four radial fibre optic connections.
  • The CCMHB-BA hub expansion box provides additional slots for up to 8 fibre optic connections. Two standard length, single-mode fibre optic cables are available (BN34R-10 and BN34R-31); however, users normally provide this connection. Customers should reference the TIA/EIA 568-A Commercial Building Telecommunications Cabling Standard, Section 12.3.4. Fibre optic connectivity is completely transparent to the systems using it and has no performance impact.
PCI System Area Network controller, maximum two per system, one per PCI bus

CCMAB-AA

System Area Network hub with 4 line cards; includes BN19P-2E power cord for Canada, Japan, and US operations; country-specific power cord for other regions is required

CCMHB-AA

MEMORY CHANNEL hub expansion box with no line cards

CCMHB-BA

Expansion line card for CCMHB hub

CCMLB-AA

1-m cable for CCMAB, CCMHB, and CCMFB

BN39B-01

4-m cable for CCMAB and CCMHB

BN39B-04

10-m cable for CCMAB and CCMHB

BN39B-10

Copper-to-single mode fibre optic converter; CCMFB must reside on the same power/PCI bus as the node’s PCI MC adapter module (CCMAB) that it services. It may also reside in same hub enclosure (up to four nodes) or a second hub enclosure (from 5-8 node utilization).

CCMFB-AA

10-m fiber optic cable

BN34R-10

31-m fiber optic cable

BN34R-31

MEMORY CHANNEL Power Cords
Australia, New Zealand

BN19H-2E

Central Europe

BN19C-2E

Denmark

BN19K-2E

Egypt, India

BN19S-2E

Ireland, United Kingdom

BN19A-2E

Israel

BN18L-2E

Italy

BN35M-02

Switzerland

BN19E-2E

MEMORY CHANNEL (Requirements for Currently Installed AlphaServer 8400 systems)
  • Console firmware at revision V2.3 or higher
  • CCMAA-BA adapter must be installed in slots 0-7 of a DWLPA-AA/AB/BA/BB PCI; no restriction for
    DWLPB-AA/AB/BA/BB PCI bus
  • For two system nodes, order one CCMAA-BA per system and one BC12N-10 cable to connect them.
  • For three or more system nodes, order CCMHA-AA (MEMORY CHANNEL Hub) one CCMAA-BA and one BC12N-10 cable per system node.
  • CCMHA-AA (MEMORY CHANNEL Hub) is configured with four CCMLA-AA Line Cards and supports up to four nodes. Expansion up to eight system nodes can be achieved by adding up to four additional CCMLA-AA Line Cards, except TruCluster Production Server configurations
PCI to MEMORY CHANNEL controller, maximum two

CCMAA-BA

MEMORY CHANNEL Hub with four line cards

CCMHA-AA

MEMORY CHANNEL Line Card for use with MEMORY CHANNEL Hub (CCMHA-AA)

CCMLA-AA

MEMORY CHANNEL cable

BC12N-10

TruCluster Production Server Software for Tru64 UNIX

QB-3RLAQ-AA

Tru64 UNIX Driver for MEMORY CHANNEL license

QB-4ZCAQ-AA

OpenVMS Cluster license for Alpha systems

QL-MUZAQ-AA

CCMHA-AA, MEMORY CHANNEL Hub, includes BN19P-2E line cord for Canada, Japan, and U.S. operation. For other regions, order power cords listed above.
Step 11 - Console Terminal - Required unless terminal is available onsite.
  • VT console terminal with EIA-232 25-pin DSUB connector is required, (even with KFE72 installed) for system power-up, diagnostics, and console display; order unless otherwise available.
  • Shielded console cable is included for connection to console terminal.
VT510 terminal

VT510-xx

Step 12 - Graphics Support for Tru64 UNIX - Optional
  • Graphics support for GS140 and 8400 running Tru64 UNIX V4.0D or later can be provided through the combined use of KFE72-EA port option and the SN-PBXGB-TL graphics adapter.
  • SN-PBXGB-TL requires 17² or 21² Professional Series monitor and keyboard for graphics support unless
    available onsite
  • Selection of video extension cable and country-specific power cord required for all monitor variants
  • EISA or ISA options are not supported on KFE72-EA subsystem
Graphics console subsystem for Tru64 UNIX systems, includes diskette drive and mouse; KFE70-AA and KFE72-EA are not supported concurrently on the same system; however, either option can be used to run RAID Configuration Utility (RCU).

KFE72-EA

GSxxx/8x00 graphics adapter

SN-PBXGB-TL

Step 13 - Tru64 UNIX and OpenVMS Partitions - Optional
  • A single GS140 can be divided into a maximum of three logical hardware partitions. Each partition is allocated its own set of hardware resources- CPU, memory, I/O module. Partitioning support requiresTru64 UNIX V4.0F or later, or OpenVMS V7.2 or later operating system and partitioning licenses.
  • System Console Firmware Revision 5.4 or later required
  • Each partition requires a minimum of one CPU module, one memory module, one I/O module, and one DWLPB
    (PCI and PIU shelf) per partition.
  • Each partition must have a dedicated console terminal. The first partition will obtain this support in a standard manner via the server console panel. The second and third partition requires a KFE72-DA to obtain this console support. H8571-J adapter is required to connect KFE72-DA to the console terminal;
    KFE72-DA does not include a diskette drive, which is required to support RAID Configuration Utility (RCU). Order KFE72-EA if a floppy or graphic support is required.
  • For more information regarding Tru64 UNIX V4.0F partitioning configuration hardware guidelines and console partition commands, see Tru64 UNIX V4.0F SPD 41.61.22 and Tru64 UNIX V4.0F System Administration Guide, Appendix E.4.
  • For more information regarding OpenVMS Galaxy partitioning guidelines and support, see http://www.openvms.digital.com/availability/GALAXY.html
  • Existing AlphaServer 8400 users can upgrade their system to an AlphaServer GS140 level system that supports hardware partitions with a CPU upgrade (dual Alpha 21264A 6/700-MHz CPU modules), Operating System upgrade (Tru64 UNIX V4.0F or later), and System Console Firmware Revision 5.4 or later; additional hardware may be required to support hardware partitions.
Minimum Hardware Required per GS140 Partition
  • Dual Alpha 21264A 6/700-MHz CPU module
  • MS7CC-EA/FA/GA memory module (1 GB, 2 GB, 4 GB)
  • KFTHA-AA or KFTIA-AA I/O module (KFTIA for installed base only)
  • DWLPB-xx PCI Plug-in Unit
  • KFE72-DA/EA serial port console (used for second and third instance of Tru64 UNIX or OpenVMS Galaxy)
  • Console terminal with shielded console cable for each partition
  • CD-ROM reader (or network adapter) is required per partition; additional SCSI CD-ROMs can be configured in StorageWorks shelf using supported I/O adapters
  • Tru64 UNIX Hardware Partition license per partition for second and third partition support (QM-MT4AA-AA)
  • OpenVMS software partition license required for each CPU in a partition (QL-66XAA-3B/3C/3D/3F)
Unsupported Options for GS140 Partitions
  • MEMORY CHANNEL, clustering of a partitioned GS140 is not supported
  • NVRAM (Prestoserve Non-Volatile Random Access Memory)
  • EISA devices
  • XMI is supported in first partition of GS140 only
  • Future Bus is not supported
  • Supported Options List (SOL) restriction rules still apply for maximum configurations of GS140 systems
Step 14 - Monitors - Optional
17² (16² viewable image size) professional series auto-scanning color monitor, Trinitron CRT, 0.25 mm aperture grill pitch, VGA to 1280 x 1024 at 75 Hz, TCO 95, MPR-II, Energy Star, attached
1.8-m video cable; requires video extension cable and country-specific power cord; Northern Hemisphere without power cord

3R-VRQP7-24

Same as above except Southern Hemisphere without power cord

3R -VRQP7-23

21² (19.6² viewable image size) auto-scanning color monitor, Trinitron CRT, 0.25 mm aperture grill pitch, VGA to 1600 x 1200 at 75 Hz NI, TCO 95, Energy Star, includes 1.8-m video cable; requires video extension cable and country-specific power cord; Northern Hemisphere without power cord

3R -VRQP1-24

Same as above except Southern Hemisphere without power cord

3R -VRQP1-23

Video Extension Cable
1.8-m video extension cable

BN39C-02

Monitor Power Cords
Australia/New Zealand

BN19H-2E

Central Europe

BN19C-2E

Denmark

BN19K-2E

India/South Africa

BN19S-2E

Israel

BN18L-2E

Italy

BN35M-02

Japan

3X-BN46F-02

North America, Japan

BN26J-1K

Switzerland

BN19E-2E

UK/Ireland/Hong Kong

BN19A-2E

Step 15 - Keyboards - Selection of country-specific keyboard required.
 

Tru64 UNIX

OpenVMS

U.S./English keyboard

SN-LKQ47-AA

LK461-A2

Arabic keyboard

SN-LKQ47-BR

-

Belgian keyboard

SN-LKQ47-AB

LK461-AB

BHCSY keyboard

SN-LKQ47-AX

-

Canadian/English keyboard

-

LK461-AQ

Canadian/French keyboard

SN-LKQ47-AC

LK461-AC

Cyrillic keyboard

SN-LKQ47-BT

LK461-BT

Czech keyboard

SN-LKQ47-BV

LK461-BV

Danish keyboard

SN-LKQ47-AD

LK461-AD

Dutch keyboard

SN-LKQ47-AH

LK461-AH

Finnish keyboard

SN-LKQ47-AF

LK461-AF

French keyboard

SN-LKQ47-AP

LK461-AP

German keyboard

SN-LKQ47-AG

LK461-AG

Greek keyboard

SN-LKQ47-BH

LK461-BH

Hebrew keyboard

SN-LKQ47-AT

LK461-AT

Hungarian keyboard

SN-LKQ47-BQ

LK461-BQ

International keyboard

SN-LKQ47-BA

-

Italian keyboard

SN-LKQ47-AI

LK461-AI

Korean keyboard

SN-LKQ47-BK

-

Latin-American keyboard

SN-LKQ47-AR

-

Norwegian keyboard

SN-LKQ47-AN

LK461-AN

Polish keyboard

SN-LKQ47-BP

LK461-BP

Portuguese keyboard

SN-LKQ47-AV

LK461-AV

Romanian keyboard

-

LK461-BL

S. Chinese keyboard

SN-LKQ47-CV

-

Slovak keyboard

SN-LKQ47-CZ

LK461-CZ

Spanish keyboard

SN-LKQ47-AS

LK461-AS

Swedish keyboard

SN-LKQ47-AM

LK461-AM

Swiss/French keyboard

SN-LKQ47-AK

LK461-AK

Swiss/German keyboard

-

LK461-AL

Taiwanese keyboard

SN-LKQ47-BI

-

Thai keyboard

SN-LKQ47-CB

-

Turkish keyboard

SN-LKQ47-BU

LK461-BU

Turkish/French keyboard

-

LK461-BW

<